Qualitative and Quantitative Image Analysis of MRCP Imaging in T2 SS-FSE and T2* FIESTA Fat Saturation

Authors

  • Hernastiti Sedya Utami Department Radiologic Imaging Technology, Health Sciences Faculty, Universitas Muhammadiyah Purwokerto
  • Lutfatul Fitriana Department Radiologic Imaging Technology, Health Sciences Faculty, Universitas Muhammadiyah Purwokerto
  • Fani Susanto Department Radiologic Imaging Technology, Health Sciences Faculty, Universitas Muhammadiyah Purwokerto
  • Pradana Nur Oviyanti Departement of Radiology, Faculty of Medicine, Universitas Muhammadiyah Purwokerto

DOI:

https://doi.org/10.55927/mudima.v2i12.1991

Keywords:

MRCP, SS-FSE, FIESTA, Fat Saturation, Biliary System

Abstract

The T2 weighted imaging of coronal MRCP can used a sequence derived from spin echo is the SS-FSE sequence and the gradient echo fast imaging is FIESTA. SS-FSE can be done with the fat saturation technique to suppress the fat signal so that it will be hypointense. The use of the breath-hold technique can also be used in both sequences. This study was to compared the differences in coronal MRCP image information between SS-FSE and FIESTA fat saturation to evaluate their ability to depict the image quality of MRCP. 15 patients performed 2D T2 SS-FSE and FIESTA fat saturation coronal MRCP. The images analyzed by qualitative study that was carried out by MRCP questionnaire which was examined by radiologist. Quantitative analysis was conducted by measuring the signal-to-noise ratio (SNR) values. The result is the FIESTA fat saturation sequence shows better image information and more optimized SNR than the SS-FSE on coronal MRCP because it can reveal more clear and informative anatomy such as common bile duct, pancreatic duct, cystic duct and intrahepatic duct. Finally, FIESTA fat saturation can be used as a effective alternative sequence and can improve billiary system of MRCP image quality

References

Andrea, A., Kircher, M.F., Borgheresi, A., Monti, S., Giovagnoni, A., & Manneli, L. (2016). Magnetic Resonance Imaging of the Liver (Includng Biliary Contrast Agents)-Part 2: Protocols for Liver Magnetic Resonance Imaging and Characterization of Common Focal Liver Lesions. Semin Roentgenol, 51(4), 317–333.

Bushong, S. C. (2017). Radiologic science for technologists : physics, biology, and protection (ELEVENTH EDITION). Elsevier Inc.

Chavhan, G.B., Babyn, P.S., Jankharia, B.G., Cheng, H.L.M., & Shroff, M.M. (2008). Steady-State MR Imaging Sequences: Physics, Classification, and Clinical Applications. RSNA, 28:1147–1160

Elmaoglu, M., and Celik, A., (2012). MRI Handbook: MR Physics, Patient Positioning, and Protocols. Springer: Germany

Elster, A.D. (2007). True FISP: What is True FISP, and why is it “truer” than regular FISP?. ElsterLLC. Retrieved from http://mriquestions.com/true-fispfiesta.html

Frisch, A., Walter, T. C., Hamm, B., & Denecke, T. (2017). Efficacy of oral contrast agents for upper gastrointestinal signal suppression in MRCP: A systematic review of the literature. Acta Radiologica Open, 6(9), 1–7. https://doi.org/10.1177/2058460117727315

Grande, F. Del, Santini, F., Herzka, D. A., Aro, M. R., Dean, C. W., Gold, G. E., & Carrino, J. A. (2014). Fat-suppression techniques for 3-T MR imaging of the musculoskeletal system. Radiological Society of North America, 34(1), 217–233. https://doi.org/10.1148/rg.341135130

Kuperman, V. (2000). Magnetic Resonance Imaging: PHYSICAL PRINCIPLES AND APLLICATIONS. Academic Press.

Moeller, T. B., & Reif, E. (2003). MRI Parameters and Positioning (Second Edi). Thieme Stuttgart

Naraghi, A., & White, L. M. (2012). Three-dimensional MRI of the musculoskeletal system. American Journal of Roentgenology, 199(3), 283–293. https://doi.org/10.2214/AJR.12.9099

Pezeshk, P., Alian, A., & Chhabra, A. (2017). Role of chemical shift and Dixon based techniques in musculoskeletal MR imaging. European Journal of Radiology, 94, 93–100. https://doi.org/10.1016/j.ejrad.2017.06.011

Pressacco, J., Reinhold, C., Barkun, A. ., Barkun, J. ., Valois, E., & Joseph, L. (2003). Accuracy of MRCP vs . ERCP in the Evaluation of Patients with Bile Duct Obstruction in the Setting of a Randomized Clinical Trial. Proc. Int. Soc. Mag. Reson. Med, 11, 412.

Safitri, Indah Dewi. (2017). PROSEDUR PEMERIKSAAN MAGNETIC RESONANCE CHOLANGIOPANCREATOGRAPHY (MRCP) PADA KLINIS CHOLELITIASIS DI INSTALASI RADIOLOGI MRCCC SILOAM HOSPITAL SEMANGGI JAKARTA SELATAN. Poltekkes Kemenkes Semarang [Skripsi]

Singh, A., Mann, H. S., Thukral, C. L., & Singh, N. R. (2014). Diagnostic accuracy of MRCP as compared to ultrasound/CT in patients with obstructive jaundice. Journal of Clinical and Diagnostic Research, 8(3), 103–107. https://doi.org/10.7860/JCDR/2014/8149.4120

Vitellas, K. M., Keogan, M. T., Spritzer, C. E., & Nelson, R. C. (2000). MR Cholangiopancreatography of Bile and Pancreatic Duct Abnormalities with Emphasis on the Single-Shot Fast Spin-Echo Technique. RSNA, 20(4), 939–957. http:

Westbrook, C., Kaut Roth, C., & Talbot, J. (2011). MRI in pactice (4th ed.). Blackwell Publishing Ltd.

Downloads

Published

2022-12-28

How to Cite

Hernastiti Sedya Utami, Lutfatul Fitriana, Fani Susanto, & Pradana Nur Oviyanti. (2022). Qualitative and Quantitative Image Analysis of MRCP Imaging in T2 SS-FSE and T2* FIESTA Fat Saturation . Jurnal Multidisiplin Madani, 2(12), 4260–4266. https://doi.org/10.55927/mudima.v2i12.1991