Investigating the Effect of Direct Touch Method on Insulator Replacement in Candra Asri Feeder

Authors

  • I Wayan Dikse Pancane Universitas Pendidikan Nasional

DOI:

https://doi.org/10.55927/fjsr.v3i2.7985

Keywords:

Support Insulator, PDKB, Editor, SAIDI, SAIFI

Abstract

PLN UP3 East Bali in carrying out Fulcrum Insulator maintenance chooses to use Work In Direct Touch Voltage status. The purpose of using this method is to reduce the value of reliability indices in the form of System Averange Interruption Duration Index, System Averange Interruption Frequency Index, and Saving kWh which results in rupiah savings. The results showed that in 11 times the replacement work of the Fulcrum Insulator extinguishing method resulted in a SAIDI value of 0.105 minutes per customer, SAIFI of 0.104 times per customer. Meanwhile, if done with the Direct Touch method, PDKB gets a SAIDI and SAIFI value of 0. So if done with the Direct Touch Method, PDKB gets embedded 32,903.67 kWh and Rp. 42,248,314.85

Downloads

Download data is not yet available.

References

Alam, A. (2021). Optimal placement of reclosers in a radial distribution system for reliability improvement. Electronics (Switzerland), 10(24). https://doi.org/10.3390/electronics10243182

Dewi, T. P. (2021). Analisa Penurunan Tahanan Isolasi Pin Type Insulation Porselin Penyulang Sungkai Gardu Induk Bungaran Di Ulp Ampera Pt Pln …. eprints.polsri.ac.id.

Eka, A., Lestari, P., Oetomo, P., Industri, F. T., & Selatan, J. (2021). Analisis Pemilihan Penghantar Tenaga Listrik Paling Effisien Pada Gedung Bertingkat. Program Studi Teknik Elektro - ISTN Sinusoida, XXIII(2), 61–68.

Gonzalez, M. (2019). Improvement of SAIDI and SAIFI reliability indices using a shunt circuit-breaker in ungrounded MV networks. IET. https://doi.org/10.1049/cp.2013.0565

Juliasandi, A., & Alfi, I. (2021). Analisa kwh Terselamatkan Pada Pemeliharaan Absw (Air Break Switch) Dengan Metode Pdkb (Pekerjaan Dalam Keadaan Bertegangan) Di PT. PLN (Persero) Distribusi Jawa Tengah Dan D.I. Yogyakarta Rayonpurwokerto. 1–11.

Kruithof, M., Hodemaekers, J., & ... (2020). Quantitative risk assessment; A key to cost-effective SAIFI and SAIDI reduction. CIRED 2005-18th …. https://ieeexplore.ieee.org/abstract/document/5427985/

LaCommare, K. H., & Eto, J. H. (2006). Cost of power interruptions to electricity consumers in the United States (US). Energy. https://www.sciencedirect.com/science/article/pii/S036054420600051X

Leksana, R. P. (2020). Studi Penerapan Pdkb Pada Saat Penggantian Isolator Terhadap Pasokan Listrik Di Pt Pln (Persero) Area Purwokerto.

Mahadewi, K. M., Janardana, I. G. N., & ... (2019). Analisis Tegangan Langkah dan Tegangan Sentuh serta Perencanaan Sistem Pembumian pada Pembangunan Substation VVIP di Bandar Udara …. In J …. download.garuda.kemdikbud.go.id.

Manopo, K. G., Tumaliang, H., & Silimang, S. (2020). Analisis Indeks Keandalan Sistem DistribusiTenaga Listrik Berdasarkan SAIFI dan SAIDI PadaPT. PLN (Persero) Area Minahasa Utara. 1–12.

Nanda, T. D. (2021). Pengaruh Pelatihan K3 Dan Komitmen Kerja Terhadap Prestasi Kerja Karyawan Pada PT. Swadaya Abdi Manunggal. repository.uir.ac.id.

Pancane, I. W. D. (2022). keselamatan dan kesehatan kerja. 1, 72.

Piasson, D. (2020). A new approach for reliability-centered maintenance programs in electric power distribution systems based on a multiobjective genetic algorithm. In Electric Power Systems Research (Vol. 137, pp. 41–50). https://doi.org/10.1016/j.epsr.2016.03.040

Priyatno, H. (2023). Peralatan Inovasi Live-Line Maintenance : Temporary Cross Arm Support Insulator. ELECTRON Jurnal Ilmiah Teknik Elektro, 4(1), 01–09. https://doi.org/10.33019/electron.v4i1.31

Putranto, H. (2019). Pengembangan e-modul online instalasi listrik, pemasangan, dan keamanan instalasi pada pendidikan jarak jauh. Teknologi Dan Kejuruan: Jurnal Teknologi, Kejuruan ….

Rahmaniar, R., Syahputra, M. R., & ... (2022). Sosialisasi Pemahaman Bahaya Tegangan Sentuh Dan Hubung Singkat Sistem Kelistrikan Bagi Masyarakat Desa Kota Pari. RESWARA: Jurnal ….

Rizky, A. O. (2020). Komputasi Pembumian Peralatan Pada Gardu Induk. Universitas Brawijaya.

Rohadi. (2021). Implementasi Manajemen Energi Pada. Universitas Islam Sultan Agung.

Sampoerna, G. B. (2020). Desain sistem pentanahan gardu 150 KV dengan menggunakan standar IEEE 80-2013 pada PT Bekaert Indonesia. SKRIPSI-2018.

Saputra, I., Sugiarta, I. N., & Sudiartha, I. W. (2023). Analisis Saidi Saifi dan ENS dalam Penggantian Isolator Tumpu Terhadap Keandalan Sistem dengan Metode Sentuh Langsung pada Penyulang Candra Asri. repository.pnb.ac.id. http://repository.pnb.ac.id/10441/

Saputra, W. A. (2022). Analisa Pengaruh PDKB pada Pekerjaan Pemeliharaan Isolator Tumpu di Penyulang 10 GI Sayung 150/20 kV Demak. Unissula Institutional Repository, 1–66.

Suryadi, A., & Sofwan, A. (2021). Rancang Bangun Modul Simulasi ELCB Fasa Satu Sebagai Pelindung Bagi Manusia. SAINSTECH: JURNAL PENELITIAN DAN ….

Swamardika, I. B. A., Amrita, A. A. N., Arjana, I. G. D., & ... (2019). Pelatihan Pengaman Instalasi Listrik sesuai Persyaratan Umum Instalasi Listrik 2011 Serta Amandemen 2014. In Buletin Udayan …. ojs.unud.ac.id.

Widyastuti, C., Handayani, O., & Koerniawan, T. (2021). Keandalan Sistem Penyaluran Listrik Berdasarkan Saidi Dan Saifi Sebelum Dan Sesudah Pemasangan Kubikel Arrester di PT PLN UP3 Serpong. Energi & Kelistrikan, 13(2), 95–103. https://doi.org/10.33322/energi.v13i2.1031

Downloads

Published

2024-02-28

How to Cite

Pancane, I. W. D. . (2024). Investigating the Effect of Direct Touch Method on Insulator Replacement in Candra Asri Feeder. Formosa Journal of Sustainable Research, 3(2), 245–254. https://doi.org/10.55927/fjsr.v3i2.7985